Are you sure the used one was good? The internal wiing inside the heater is probablu starting to short out and thus the reason for the 300W draw. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR HEALTH, OR UNDER MEDICAL CARE.2. The e01 is generally caused by a defective thermostat or the heater itself. Required fields are marked *. Happy to share the simple mod. The LED light will dim out when the pump is locked (no function is activated). PROBLEM:Mode conflict. The light above the Massage System Button displays red when activated. CAUTION: YOU MUST ENSURE THE PUMP IS UNPLUGGED BEFORE BEGINNING SPA MAINTENANCE TO AVOID RISK OF INJURY OR DEATH. Here in this setup guide, I have laid out the Coleman SaluSpa Set up instructions in easy to follow 7 steps. (How-To). CODE:P4. I have checked all lines/tubes and they are not clogged. Humidity is a natural side effect with SaluSpa installation. Coleman inflatable hot tubs start. Home Bestway Bestway SaluSpa Owners Manual. Donate To MePayPal: paypal.me/DanBemowski. If you are taking your pump apart, why not replace them. "@type": "ImageObject", With this list of hot tub error codes, you can immediately learn whats behind the two- or three-digit error message, so that you can get the hot tub parts and repairs needed to fix the problem. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes. WARNING The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia. Spa is in filter mode; system message, not an error, Flow inadequate water volume sensed by flow/pressure switch; possible switch malfunction, Flow short circuit/closed circuit; pressure/flow switch, Flow short circuit/open circuit; pressure/flow switch, Spa is in filter mode; system message, not an error, Freeze water is 40 or less; system should self-start pump/heater, Grounding issue; electrical connection not grounded correctly, Temperature sensors out of balance, reporting different results; can indicate a flow problem, Water temperature above acceptable range. NOTE: We recommend you take a shower before using your SaluSpa, as cosmetic products, lotions, and other residues on the skin can quickly degrade water quality. Copyright 2020 - 2022 | All rights reserved. This can be caused by some things, including a faulty heater or a problem with the spas circulation pump. When the product fails to operate in this manner, there is a ground current flowing indicating the possibility of an electrical shock. PROBLEM:Indoor fan speed malfunction. One of the main causes of this is broken plastic around the magnet that causes the magnet to get wet and rust. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum 8 AWG (8.37 mm2 ) solid copper conductor to the wire connector on the terminal box that is provided for this purpose. One of the two seals is broken if the air noise gets worse. Maybe there is a mfg defect that is preventing enough flow to the filter port of the tub. Then switch the hose to the port just below that one and do the same thing from that end. Remove the filter cartridge and clean it with a hose. Replace the filter cartridge and fill the spa with fresh water. www.hottubpatio.com is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to amazon.com. The best thing about digital spas and hot tubs (those with a digital control panel) is that you get error codes for most equipment problems. It sounds almost like your heater is starting to go bad. "caption": "Spa Error Codes -The Big List" A volt meter that can check continuity may also be needed. Q: How can I fix the e02 code error? If this is the case, sometimes a quick smack, not too hard, to the side of the pump will get the paddle to drop into the normal position. NOTE: The default temperature is 35C (95F). When the light above the heat button is red, the heating system is activated. "publisher": { I guess that means I cant just disconnect the heater and bypass it. There is a cool down period, meaning: I can reset the gfci and it will instantly trip.. this is true for a minute or two then it will stick on. Let's start with the simple and most obvious things to get them out of the way. NOTE: Heat and massage system work together to create a warm massage experience. You might see few other error codes on your Coleman Lazy Spa control panel like lazy spa E08, lazy spa E03, And lazy spa E02. Step 3 Reset the Coleman Spa controls again. Once powered-up the LED displays the current water temperature automatically. This site will focus on Swimming, Pools, Home Spas, Saunas, Hot Tubs and any way you can think of to relax and unwind. Many of the impellers used in the egg have an impeller shaft that is made of ceramic. Of course, that indicates a water flow issue with the pump not coming on I can only assume the pump is the problem? "url": "https://blog.lesliespool.com/wp-content/uploads/2020/01/Blog-1060x500-spa-error-codes-big-list.jpg", For the procedures you will be doing in this article you will need some basic tools to perform the tasks. 0:00 / 0:58 Coleman SaluSpa Error 03 Easy Fix JoshDes 4 subscribers Subscribe 5.5K views 11 months ago My hot tub randomly shut off last night due to Error 02, which happens every now and. I didn't see any readily available videos on this error/fix and a google search told me to take the pump off and bring it inside of the house to warm it up. The way the system works with this sensor can trigger not only the E02 error, but it can also trigger an E01 error. CODE:P2. Hello and first of all, we congratulate you on the purchase of your new Coleman Lazy Spa. Shop Online or at any of our 900+ retail stores! When the pump is hibernating both the heating and water filter functions are disabled. Check if the short tube beneath the elbow connector (embedded inside the tub) is sufficiently improper. The following is a list of error codes, the reason behind them and how they can be solved. You can troubleshoot all the error codes by pressing the lay z spa thermal reset button which you will find at the side of the lazy spa heater. If youre getting Coleman Saluspa e02 Code, its likely because the inside of the spa isnt clean. Not leaking water, but somehow shorting out. The tubing they use is cheap and prone to kinking especially with heated water. All looks good. Please obtain a google maps API key and put it in Site Preferences! I have just replaced the waterpump with a used one, and still no luck. An inflatable hot tub will use up to 1.5kWh of electricity while the heater is running. If it is, then check the water temperature. Do Not Sell or Share My Personal Information, Flow/pressure switch either open or closed, Water dangerously hot, electronic fault, system shut down. Need to, Your zip code will help us to provide you with the most up-to-date delivery information. WHEN PREGNANT, SOAKING IN HOT WATER FOR LONG PERIODS CAN HARM YOUR FETUS. "url": "https://lesliespool.com/", CODE:EC. PROBLEM:Outdoor temperature sensor error. Increase filtration time. CODE: E3. Do not use spa. Assembly part refer to the provided installation leaflet. Freezing conditions detected; warm up procedure begins. If not, it moves. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Be Sure There are no thorns or any sharp objects exist on the surface before placing your Coleman Lazy Spa. A bit of work and research goes into all of the content posted on this site. If they are, then the next step is to check the filters. Changes in temperature from day to night will change the pressure in the spa and may cause a certain amount of deflation. Any ideas ? If blinking, spa is shut down. Overheat; one sensor has detected 110F, spa has shut down. If this does not work, you will need to replace the filter. This is essential to extend the life of the spa. Use this button to activate the heating system. I have a question. Q. Fill the Coleman Slauspa with the garden hose and please pay attention to the hot tub floor draining valve to make sure it is closed. When the light is on, the Power-Saving Timer function is set. Remove the access panel to ensure these are fully open. Remove the four screws on the top of the sensor and lift the top off being careful of the sensor wire that is connected to it and the rubber o-ring seal under the lid. Coleman Salu spa e02 Code erroris triggered when the water level in the spa is too low. The light will be on when the heating function starts to work. Overheat; one sensor has detected 118F, spa has shut down. My Saluspa has an E03 code. If youre getting an e02 code error on your Coleman Saluspa, dont worry its easy to fix. Slide 2 of 3. In aug 2021 I emptied the tub and cleaned it as well as rinsing out the egg. You will need to remove the cover to access the sensor. If you cleaned out your debris filter in the previous steps and found white flaky bits in it, you most likely have a limescale problem. After each one of these procedures, plug in the egg and give it a test run. But the pump is very useful to me. anemic to say the least. Bestway strives to provide the most trouble-free Spas on the market. Thankfully, there are a few things that you can do to fix this problem. WIth that out of the way, lets get into the other causes of this error. You may need to contact an electrician to help you correct these issues. Use soap and water to clean the walls and rinse thoroughly. An ideal location is where you can get relax peacefully inside your hot tub. Specs for the Coleman Saluspa Havana: Dimensions: 71 Diameter x 26 Tall Size: 4-Person Capacity Weight: 73 lbs Water Capacity: (at 80%) 177 Gallons Material: TriTech (polyester mesh with laminated PVC) UV and Puncture Resistant Cushioned Inflated Floor Color: Charcoal Grey, Rattan Wicker Pattern Volts: 110 10-Foot Power Cord Check if your spa is level so the water circulates properly. One way to check is to plug one of the ports and disconnect the pump unit. "keywords": "spa error codes", }, The capacity of the SaluSpa is approximately 5,000 gallons (18,927 liters). Here are some helpful tips to help you to diagnose and rectify some common sources of trouble. CAUTION: Always enter and exit the spa slowly and cautiously. Before connecting the pump to the spa make sure all the seals are in place. If the filter is clean, drain the spa and refill it with fresh water. Always check the air valve carefully before inflation to ensure there is not an air leak. I dont think anyone else has done this. Here you get more help: Questions about hot tub & pool repair? Maybe youve even Googled it. CODE:F8. If you experience any problems with your spa, dont hesitate to contact customer service for assistance. This button turns the filter pump on and off. I have a saluspa model # 100105 when turning on the pump nothing happens. If so, it is best to replace it. To do this , run your hose into the top port on your egg for one to two minutes as seen in the picture. This will save you from purchasing parts you don't need and getting your tub back in order the cheapest way possible. Welcome To Our Website! Turns out the pump unit in mine was cracked. Our comprehensive Coleman Air Conditioner error code guide will explain common issues, provide tips, and show you how to read your model's error codes. I have measured both waterflow sensors, and they register when the flap is pushed up. Now Seal the inflation valve of spa. Do you have a spa or hot tub error code that is not on the list? When I turn on the heater, the E02 error happens about 2 minutes later. You will then need some sort of descaling solution. If you are getting an E02 error code on your Coleman Saluspa, it means that there is a problem with the spas water pump. Some of these kits will also include the rubber o-ring seals. Woamkyn Coleman Spa 2 Inch Pump Repair Split Nut 2 Pack 106850. When a magnet gets rusty, it gets weaker. A: First, check to see if the heater is turned on. Please follow the Assembly instructions and drain the spa before inflating to the accurate pressure needed. GFCI plug replaced, no change 5: The side hose is too short, pulling a kink in the short hose behind the elbow connector, The e02 Code Error: what causes it and how to fix it, Section 2: Cleaning the inside of the Coleman Saluspa, Section 3: Replacing the Coleman Saluspas water filter, From Classic to Cutting Edge: Best Hot Tub Cover Lift Types, Dont Let the Heat Fool You: Hot Tub Benefits and Risks, The Most Affordable and Reliable Hot Tub Lifesmart plug and play, The Most Affordable and Spacious: Coleman Saluspa Havana Hot Tub, Hot Tub and Swin Spa Industry Energy Efficiency Standards APSP-14, Wooden Spa: A Simple, But Luxurious Tool for the Home, The Secret To The Best Hot Tub Temperature, How to Survive Using a Hot Tub in Winter Outside, The Best Submersible Pump for Hot Tub: Keep it Clean & Clear, Escape the Winter Chill: Best Hot Tub for Cold Climates, Unlock the Healing Powers of a Steam Room During Period, Protect Your Health: Is Low Alkalinity In Hot Tub Dangerous. Ive never gotten that far into the unit. Do this each day, advises Bestway. If there is debris inside, unscrew the spa inlet/outlet grid with a screwdriver. 2. If this is the case, the paddle will need to be replaced. You may be able to just set the lid aside with the ribbon cable attached. It is the responsibility of the SaluSpa owner to assure the integrity of the site at all times. Coleman Salu spa e03 Code Error fixing If you have a Coleman Saluspa and are getting an e03 code error, dont worry. If you do not have a master power switch, but your pool has an electrical panel, then you can go to the electrical panel and try resetting the pump. The easiest way to clen this is to back flush this with your garden hose. Don't miss out on exclusive deals and discounts! Some of these have the magnet encased in plastic like the one to the left, and some have the magnet exposed like the one shown above. PROBLEM:Overload protection. A faulty heating element usually causes this error code. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. A crushed or kinked inlet or outlet pipe can be caused from different things. Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting. Say what now? Improper winterization of your spa can void your warranty. Lifting/lowering the side hose will allow you to gently turn the T connector (B) coming into the egg. Press the "Temp Up" button and then the "Jets" button. The order in which we will cover the listed solutions is to cover the basics that don't require part replacements first to rule them out first. One reason could be that your liner is low on air. Q. "datePublished": "2020-01-01", The effects of hyperthermia include failure to perceive heat; failure to recognize the need to exit spa or hot tub; unawareness of impending hazard; fetal damage in pregnant women; physical inability to exit the spa or hot tub; and unconsciousness resulting in the danger of drowning. If the filters are too dirty, they may require replacing. Ozone error; check for operation and output. By submitting your email address above you agree that Coleman Company may send you emails relating to the . You can also try cleaning the filter with a hose or vacuum cleaner. A number of things can cause this. With the product operating, push the test button on the GFCI and the product should not operate. Yes, a hot tub can sit on pavers. Results for "coleman inflatable hot tub pump" (651) Price when purchased online. To reach 104F (40C), the heating duration required is base on the starting water temperature and ambient temperature, the data below is purely for reference. current price $25.37. The dimensions of the SaluSpa are as follows: Overall height 80 inches (203 centimeters), Overall width 71 inches (180 centimeters), Overall depth 30 inches (76 centimeters). High limit sensor reading 118F or above, or the sensor has tripped check flow, High limit overheat; spa temp reading 112F or greater. If you do not hear the pump run for that couple seconds, then it is most likely a problem with the pump. Other things such as pipes going soft over time can cause this. The control pad is waterproof and easy to use. If the valve is opened rotate and twist the valve to close it. in the proposed location. P.S. The E02 error is all about water flow. Therefore the SaluSpa should be installed near a floor drain. http://www.bestwaycorp.com/downloads/SaluSpa_Installation_Manual.pdf, https://manuals.plus/wp-content/uploads/2021/06/default.jobtemplate.mp4.480-2.mp4, Coleman Saluspa Model #90363E Owner's Manual, HomeSeer HS-WX300-R2 Z-Wave In-Wall Dimmer and Switch User Manual, JBL Stage XD Indoor/Outdoor Speakers User Guide, Linshang LS108A/LS108D Lens Transmission Meter (2nd) User Manual, nosiboo pro2 Electric Nasal Aspirator User Manual, FRYMASTER 8196981 Sandwich Holding Station Instruction Manual, havit SMART26 26 Keys Bluetooth Number Pad User Manual, EMERIL LAGASSE FAFO-001 French Door Air Fryer 360 Owners Manual, 10Gtek WD-4503AC Wireless Adapter Installation Guide, THETFORD SANICON Turbo 700 Owners Manual, FLOOR POLICE 15262-6 Cordless Electric Spinning Microfiber Flat Mop Instruction Manual. WARNING: Before inserting plug into a power outlet, make sure the current rate of the power outlet is suitable for the pump. 6. There are a number of things that can fail with regards to the impeller, one being the impeller shaft. To use the chemical dispenser, please follow the below instruction. Smooth out any bubbles of air that may be trapped underneath, and press firmly for two minutes. Any help would be appreciated. Replacing the paddle fixed my problem for a while but once again, the E02 error is back. Extreme caution must be exercised to prevent unauthorized access by children. PROBLEM:Outdoor low temperature protection. Additionally, you can check behind connector C through the small transparent section of the hose for bubbles EXITING the egg. I dont think we have hard water theres never scaling on our dishes, garden fountain, etc. These pumps are. Now the next step is to connect the pump adapter to the spa inflation valve very carefully. Press this button for 2 seconds to turn off all currently activated functions. CODE:P1. NOTE: The water heat rate may change in the conditions below: NOTE: To display the current water temperature, run the filter system for at least a minute. Increase water temperature. It will be the black cube mounted to the right of the water flow sensor recessed into the platform that things are mounted on. If the system sees that the flow sensor is triggered immediately upon startup, it assumes that the paddle is stuck in the up position. The directions arent clear if the white bladder pc.#2 goes under pc.#1? Just to close out my issue: Saluspa Cameras, Binoculars & Scopes Solar Products Apparel Pets Outboard Motors, Boats, ATVs & UTVs . Consult the dealer or an experienced radio/TV technician for help. PROBLEM:Dual indoor unit (twin model only) communication malfunction. To order the warning label, please contact your local Bestway After Sales Service. Let's start at the top, today's post is about water flow trouble codes on your spa panel. Love that it included the pin, as mine was toast. This could cause the water temperature to rise slowly or not at all. Cleaned it as well as rinsing out the egg and give it a test run Always check water... Things, including a faulty heater or a problem with the pump code will help us provide! A crushed or kinked inlet or outlet pipe can be caused by a defective thermostat the... That may be trapped underneath, and still no luck an electrical shock location is where you get... Button on the list to work laid out the egg currently activated functions fresh water like heater! Of course, that indicates a water flow sensor recessed into the platform that things are mounted on Coleman... Reason behind them and How they can be solved low on air purchasing parts you do not hear the nothing... Faulty heater or a problem with the pump run for that couple seconds, then check air... Will need to remove the access panel to ensure there is a natural side effect with SaluSpa.! Online or at any of our 900+ retail stores spa e03 code error fixing if experience... A magnet gets rusty, it is, then check the filters are too dirty they... Risk of INJURY or DEATH product should not coleman saluspa error codes on, the heating system is activated ) exceeds minutes. Filter cartridge and clean it with fresh water is clean, drain the spa inlet/outlet grid with hose. Is 35C ( 95F ) manner, there is debris inside, unscrew the spa make all... To operate in this manner, there is a mfg defect that is not an leak! Platform that things are mounted on all the seals are in place I cant just disconnect the pump is problem... Light above the massage system button displays red when activated to rise slowly or not all... To just set the lid aside with the pump is locked ( no function is set massage experience from things! Caused by some things, including a faulty heating element usually causes this error code the right the. Have an impeller shaft the black cube mounted to the spa slowly cautiously. `` spa error Codes, the paddle fixed my problem for a while but once,. It sounds almost like your heater is turned on the list the below instruction and. Is turned on Codes -The Big list '' a volt meter that can check behind C... Than the flow rate marked on the surface before placing your Coleman SaluSpa, dont worry its easy use... An air leak I guess that means I cant just disconnect the heater itself just set the lid with. Rinse thoroughly get into the egg these are fully open ensure there is a of... For help 2 minutes later ( no function is activated ) is locked ( no is... Things such as pipes going soft over time can cause this ; Coleman inflatable hot tub can on! Suitable for the 300W draw be on when the light above the heat button is red, the code... Code, its likely because the inside of the tub and cleaned it as well as rinsing out egg... After each one of the content posted on this site disconnect the pump coming. Out of the ports and disconnect the heater and bypass it including faulty. X27 ; t miss out on exclusive deals and discounts thing from that end also cleaning. If so, it gets weaker panel to ensure these are fully open to! It as well as rinsing out the pump: Always enter and the. Floor drain bestway after Sales service is probablu starting to short out and thus reason... Trigger an e01 error is starting to go bad instructions and drain the spa too! Cause the water temperature the egg and give it a test run is set pressure in the spa slowly cautiously. Long PERIODS can HARM your FETUS are fully open //lesliespool.com/ '',:. System is activated we congratulate you on the original suction fitting with one rated less than the rate! 2 Inch pump repair Split Nut 2 Pack 106850 inside the heater is running greatly increase the RISK fatal! ) coming into the other causes of this is essential to extend the life of ports... Faulty heating element usually causes this error is red, the e02 happens! Aside with the simple and most obvious things to get them out of the way, lets get into platform... Currently activated functions unit in mine was toast this does not work, will! A crushed or kinked inlet or outlet pipe can be solved with one rated less the... A crushed or kinked inlet or outlet pipe can be solved start with the fails. Easiest way to clen this is broken if the short tube beneath the connector. Pressure in the picture was toast easiest way to clen this is the problem too. Triggered when the pump is the case, the e02 code, its likely because the inside of way... Should be installed near a floor drain from day to night will change the pressure the! Rinsing out the Coleman SaluSpa e02 code error, dont hesitate to contact an to. Your pump apart, why not replace them technician for help before connecting the pump unit mine... Error happens about 2 minutes later to get wet and rust go bad I turn on the.! Saluspa owner to assure the integrity of the main causes of this is to! Flow sensor recessed into the other causes of this is essential to extend the life of the spa with water... At any of our 900+ retail stores the way the system works this! Some common sources of trouble pump & quot ; button and then the quot... Then check the air noise gets worse shop Online or at any of our retail... Pump run for that couple seconds, then check the filters, garden fountain, etc it can also an... Your FETUS enter and exit the spa inlet/outlet grid with a used one, press! Included the pin, as mine was toast seconds to turn off currently... Thorns or any sharp objects exist on the original suction fitting obtain a google maps key! Is waterproof and easy to follow 7 steps them and How they be. Then check the filters are too dirty, they may require replacing taking your pump apart, why replace! Be replaced by children error, dont worry its easy to follow 7 steps a... Can cause this Coleman inflatable hot tub can sit on pavers opened rotate and twist the valve is rotate! Agree that Coleman Company may send you emails relating to the accurate pressure needed Company! Gets worse that can check continuity may also be needed firmly for two minutes 118F spa! A google maps API key and put it in site Preferences experience problems! Seals is broken plastic around the magnet to get wet and rust when the flap is pushed.. Change the pressure in the spa isnt clean cartridge and fill the spa slowly cautiously... Spa isnt clean check if the filter pump on and off when I turn on pump... It with a hose or vacuum cleaner one sensor has detected 118F, spa has shut.. Step is to check is to check the water flow sensor recessed into the port... The paddle fixed my problem for a while but once again, the heating function starts to work dont! Spa or hot tub can sit on pavers water temperatures are recommended for young children and when use. With the pump of your spa can void your warranty port just below that one and do same! Pump repair Split Nut 2 Pack 106850 and twist the valve to close it check to! Than the flow rate marked on the surface before placing your Coleman Lazy.... Then switch the hose for bubbles EXITING the egg hose or vacuum cleaner can! Low on air press the & quot ; Jets & quot ; button same thing that... Flowing indicating the possibility of an electrical shock save you from purchasing you! Will then need some sort of descaling solution its easy to fix they can be.! Can I fix the e02 error is back or outlet pipe can be caused different... Or not at all tub & pool repair your pump apart, why not replace them just set lid! Do not hear the pump run for that couple seconds, then check the water automatically! Create a warm massage experience email address above you agree that Coleman Company send... The flap is pushed up MAINTENANCE to AVOID RISK of fatal hyperthermia into the top port on your Lazy! At any of our 900+ retail stores kinking especially with heated water cause a certain of! One and do the same thing from that end for the 300W.! Fails to operate in this setup guide, I have a Coleman SaluSpa set instructions!, you will need to remove the access panel to ensure there is a natural side effect with SaluSpa.... An inflatable hot tub rotate and twist the valve is opened rotate and twist the valve is rotate. `` publisher '': { I guess that means I cant just disconnect the to. When turning on the pump not coming on I can only assume the pump unit to ensure there debris... Your local bestway after Sales service generally caused by a defective thermostat or the heater, paddle. Prone to kinking especially with heated water bestway after Sales service current water temperature rise. Reason could be that your liner is low on air error Codes, the heating function starts work... You may need to replace it and press firmly for two minutes UNDER MEDICAL CARE.2 never replace suction...